IMO MR-1PVM 1 Phase Voltage Monitoring Relay EB5N3-3B

£100.00

3 in stock

SKU: EB5N3-3B Categories: ,

Description

WE ARE RICH ELECTRONICS

PURCHASERS OF SURPLUS

ELECTRONIC COMPONENTS

AND EQUIPMENT!

For sale here we have the above part…

1 Piece

Monitoring Relay MR Series
3-Phase current/voltage monitoring
Multifunction
Fault latch
Supply voltage selectable via power modules
2 Change-over contacts
Width 22.5mm
Industrial design

Voltage monitoring 1-phase, multifunction, modular supply

MR-1PVM
1. Functions
AC/DC voltage monitoring in 1-phase mains with adjustable
thresholds, timing for start-up suppression and tripping delay
separately adjustable and the following functions (selectable by means of rotary switch)
OVER Overvoltage monitoring
OVER+LATCH Overvoltage monitoring with fault latch
UNDER Undervoltage monitoring
UNDER+LATCH Undervoltage monitoring with fault latch
WIN Monitoring the window between
Min and Max
WIN+LATCH Monitoring the window between
Min and Max with fault latch
2. Time ranges
Adjustment range
Start-up suppression time: 0s 10s
Tripping delay: 0.1s 10s
3. Indicators
Green LED ON: indication of supply voltage
Green LED flashing: indication of start-up suppression time
Yellow LED ON/OFF: indication of relay output
Red LED ON/OFF: indication of failure
of the corresponding threshold
Red LED flashing: indication of tripping delay
of the corresponding threshold
4. Mechanical design 5. Input circuit
Self-extinguishing plastic housing, IP rating IP40 Supply voltage:
Mounted on DIN-Rail TS 35 according to EN 50022 12 to 400V AC terminals A1-A2 (galvanically separated)
Mounting position: any selectable via power supplies MR-PS
Shockproof terminal connection according to VBG 4 (PZ1 required), Tolerance: according to specification
IP rating IP20 of power module
Tightening torque: max. 1Nm Rated frequency: according to specification
Terminal capacity: of power module
1 x 0.5 to 2.5mm² with/without multicore cable end Rated consumption: 2VA (1.5W)
1 x 4mm² without multicore cable end Duration of operation: 100%
2 x 0.5 to 1.5mm² with/without multicore cable end Reset time: 500ms
2 x 2.5mm² flexible without multicore cable end Residual ripple for DC: –
Drop-out voltage: >30% of the supply voltage
Overvoltage category: III (according to IEC 60664-1)
Rated surge voltage: 4kV
6. Output circuit 7. Measuring circuit
2 potential free change-over contacts Fusing: max. 20A (according to UL 508)
Rated voltage: 250V AC Measured variable: DC or AC Sinus (16.6 to 400Hz)
Switching capacity (distance 750VA (3A / 250V AC) Input:
Switching capacity (distance 1250VA (5A / 250V AC) 30V AC/DC terminals E-F1(+)
Fusing: 5A fast acting 60V AC/DC terminals E-F2(+)
Mechanical life: 20 x 106 operations 300V AC/DC terminals E-F3(+)
Electrical life: 2 x 105 operations Overload capacity:
at 1000VA resistive load 30V AC/DC 100Veff
Switching frequency: max. 60/min at 100VA resistive load 60V AC/DC 150Veff
max. 6/min at 1000VA resistive load 300V AC/DC 440Veff
(according to IEC 947-5-1) Input resistance:
Overvoltage category: III (according to IEC 60664-1) 30V AC/DC 47k:
Rated surge voltage: 4kV 60V AC/DC 100k:
300V AC/DC 470k:
8. Accuracy Switching threshold
Base accuracy: ±5% (of maximum scale value) Max: 10% to 100% of UN
Frequency response: -10% to +5% (at 16.6 to 400Hz) Min: 5% to 95% of UN
Adjustment accuracy: d5% (of maximum scale value) Overvoltage category: III (according to IEC 60664-1)
Repetition accuracy: d2% Rated surge voltage: 4kV
Voltage influence: d0.5%
Temperature influence: d0.1% / °C
9. Ambient conditions
Ambient temperature: -25 to +55°C (according to IEC 68-1)
-25 to +40°C (according to UL 508)
Storage temperature: -25 to +70°C
Transport temperature: -25 to +70°C
Relative humidity: 15% to 85%
(according to IEC 721-3-3 class 3K3)
Pollution degree: 3 (according to IEC 60664-1)
Vibration resistance: 10 to 55Hz 0.35mm
(according to IEC 68-2-6)
Shock resistance: 15g 11ms (according to IEC 68-2-27)

When the supply voltage U is applied, the output relays switch into on-position (yellow LED illuminated) and the set interval of the start-up suppression (START) begins (green LED U flashes). Changes of the
measured voltage during this period do not affect the state of the output relay. After the interval has expired the green LED is illuminated steadily.
For all the functions the LEDs MIN and MAX are flashing alternating, when the minimum value for the measured voltage was chosen to be greater than the maximum value.
Overvoltage monitoring (OVER, OVER+LATCH)
When the measured voltage exceeds the value adjusted at the MAX-regulator, the set interval of the tripping delay (DELAY) begins (red LED MAX flashes). After the interval has expired (red LED MAX
illuminated), the output relays switch into off-position (yellow LED not illuminated). The output relays again switch into on-position (yellow LED illuminated), when the measured voltage falls below the value
adjusted at the MIN-regulator (red LED MAX not illuminated).
If the fault latch is activated (OVER+LATCH) and the measured voltage remains above the MAX-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the
measured voltage falls below the value adjusted at the MIN-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle
begins with the set interval of the start-up suppression (START).
Undervoltage monitoring (UNDER, UNDER+LATCH)
When the measured voltage falls below the value adjusted at the MIN-regulator, the set interval of the tripping delay (DELAY) begins (red LED MIN flashes). After the interval has expired (red LED MIN
illuminated), the output relays switch into off-position (yellow LED not illuminated). The output relays again switch into on-position (yellow LED illuminated), when the measured voltage exceeds the value adjusted
at the MAX-regulator.
If the fault latch is activated (UNDER+LATCH) and the measured voltage remains below the MIN-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the
measured voltage exceeds the value adjusted at the MAX-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle
begins with the set interval of the start-up suppression (START).
Window function (WIN, WIN+LATCH)
The output relays switch into on-position (yellow LED illuminated) when the measured voltage exceeds the value adjusted at the MIN-regulator. When the measured voltage exceeds the value adjusted at the MAXregulator, the set interval of the tripping delay (DELAY) begins (red LED MAX flashes). After the interval has expired (red LED MAX illuminated), the output relays switch into off-position (yellow LED not
illuminated). The output relays again switch into on-position (yellow LED illuminated) when the measured voltage falls below the value adjusted at the MAX-regulator (red LED MAX not illuminated). When the
measured voltage falls below the value adjusted at the MIN-regulator, the set interval of the tripping delay (DELAY) begins again (red LED MIN flashes). After the interval has expired (red LED MIN illuminated), the
output relays switch into off-position (yellow LED not illuminated).
If the fault latch is activated (WIN+LATCH) and the measured voltage remains below the MIN-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the measured
voltage exceeds the value adjusted at the MIN-regulator. If the measured voltage remains above the MAX-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if
the measured voltage falls below the value adjusted at the MAX-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring
cycle begins with the set interval of the start-up suppression (START).

For datasheet search…  IMO  MR-1PVM

These parts came to us as part of a lot of surplus stock from a large Milspec type Co. and have been kept in storage for some time, we have therefore classified them as ‘new other’. They are however in pristine condition still in their original packaging and ‘as new’ in all respects, the photographs are representative of their excellent condition, and, as with all our products they come with a full guarantee. 

PLEASE NOTE!

If you have similar items to this, or indeed any electronic components that are surplus to requirements please contact us with details.

Additional information

MPN

Brand